Smoke Control Damper

A compact, installation-ready smoke control damper for natural and mechanical systems – designed for performance, compliance, and simplicity on site.

System type

Natural
Mechanical

Customisations available

Lead times

Stock: 1–5 working days
Made to order: 7–8 weeks

Dedicated Sertus delivery

On time. Pre-tested. Installation-ready.

At a Glance

Fixings and mastic supplied

Hinged grille access

Insulated to I-Rating

Certified and tested for install into various wall types

Pre-drilled casing

Impact and thermal tested

Key Features

  • Compact, installation-ready smoke control damper for natural and mechanical systems 

  • Tested for 10,000+ cycles for proven long-term reliability 

  • Hinged white linear grille for easy commissioning and servicing 

  • Integrated control module with dry-fit intumescent seal for quick install 

  • Pre-drilled casing supplied with fixings and mastic – no extra components needed 

  • Suitable for both shaft and duct applications across multi-zone systems 

  • Rear duct or wall-mounted configurations 

  • Compatible with flexible, concrete, and asymmetric wall types 

Read more

Sizes & Materials

  • Standard and custom sizes available (up to 969 × 2041 mm)

  • Steel casing with multi-blade, fire-rated louvres

View size guide

Certifications

  • Certified to BS EN 12101-8:2011 - Fire resistance class EIS 120

  • Tested to EN 13501-4:2016, EN 1366-2, and EN 1366-10 

  • I-Rated and S1000 rated (up to 750 × 1400 mm) 

  • Impact tested to TN75 and TN76 (with reference to BS 8200) 

  • Bi-directional testing (i↔o) for full compliance in either orientation 

  • Automatic Activation (AA) system for fast smoke response 

  • Multi-compartment compliant - suitable for multi-zone ventilation systems  

View tech specs

Description

The Sertus Smoke Control Damper is a compact, multi-zone unit designed to provide safe and compliant smoke ventilation in both residential and commercial buildings. It is typically installed in shafts or ducted systems to enable effective smoke extract and compartmentation, supporting life safety and overall building performance.  Read more

Tech Specs

Maximum Size (W x H)

969 x 2041 mm

Opening / Closure Time

30s / 60s

Operational Reliability

Tested to 10,000 cycles

Fire Resistance – Integrity

E120

Fire Resistance – Insulation

I120

Certification

BS EN 12101-8:2011 / EN 13501-4:2016 / EN 1366-2 / EN 1366-10

Smoke Leakage

S500Pa – 1000Pa (size dependent)

Activation

AA (Automatic Activation)

Multi-Compartment Use

Suitable for multi-zone smoke ventilation

Mounting Position

VEW – suitable for vertical wall installation 

Testing Position

i↔o – tested both inside-to-outside and outside-to-inside

Impact Resistance

TN75 & TN76 (ref. BS 8200)

Material Construction

Steel casing with multi-blade fire-rated louvres 

Finish

Supplied with white linear grille

Installation Kit

Includes fixings and mastic 

Mounting Options

Rear duct or wall-mounted configurations 

Insulation / Seals

Dry-fit intumescent seal 

Function

Natural and mechanical smoke ventilation 

Fire Resistance Class

EIS 120

Size Guide

ModelOverall Width (mm)Overall Height (mm)
SLD 30.40369591
SLD 30.45369641
SLD 30.50369691
SLD 30.55369741
SLD 30.60369791
SLD 30.65369841
SLD 30.70369891
SLD 30.75369941
SLD 30.80369991
SLD 30.853691041
SLD 30.903691091
SLD 30.953691141
SLD 30.1003691191
SLD 30.1053691241
SLD 30.1103691291
SLD 30.1153691341
SLD 30.1203691391
SLD 30.1253691441
SLD 30.1303691491
SLD 30.1353691541
SLD 30.1403691591
SLD 30.1453691641
SLD 30.1503691691
SLD 30.1553691741
SLD 30.1603691791
SLD 30.1653691841
SLD 30.1703691891
SLD 30.1753691941
SLD 30.1803691991
SLD 30.1853692041
SLD 45.40519591
SLD 45.45519641
SLD 45.50519691
SLD 45.55519741
SLD 45.60519791
SLD 45.65519841
SLD 45.70519891
SLD 45.75519941
SLD 45.80519991
SLD 45.855191041
SLD 45.905191091
SLD 45.955191141
SLD 45.1005191191
SLD 45.1055191241
SLD 45.1105191291
SLD 45.1155191341
SLD 45.1205191391
SLD 45.1255191441
SLD 45.1305191491
SLD 45.1355191541
SLD 45.1405191591
SLD 45.1455191641
SLD 45.1505191691
SLD 45.1555191741
SLD 45.1605191791
SLD 45.1655191841
SLD 45.1705191891
SLD 45.1755191941
SLD 45.1805191991
SLD 45.1855192041
SLD 60.40669591
SLD 60.45669641
SLD 60.50669691
SLD 60.55669741
SLD 60.60669791
SLD 60.65669841
SLD 60.70669891
SLD 60.75669941
SLD 60.80669991
SLD 60.856691041
SLD 60.906691091
SLD 60.956691141
SLD 60.1006691191
SLD 60.1056691241
SLD 60.1106691291
SLD 60.1156691341
SLD 60.1206691391
SLD 60.1256691441
SLD 60.1306691491
SLD 60.1356691541
SLD 60.1406691591
SLD 60.1456691641
SLD 60.1506691691
SLD 60.1556691741
SLD 60.1606691791
SLD 60.1656691841
SLD 60.1706691891
SLD 60.1756691941
SLD 60.1806691991
SLD 60.1856692041
SLD 75.40819591
SLD 75.45819641
SLD 75.50819691
SLD 75.55819741
SLD 75.60819791
SLD 75.65819841
SLD 75.70819891
SLD 75.75819941
SLD 75.80819991
SLD 75.858191041
SLD 75.908191091
SLD 75.958191141
SLD 75.1008191191
SLD 75.1058191241
SLD 75.1108191291
SLD 75.1158191341
SLD 75.1208191391
SLD 75.1258191441
SLD 75.1308191491
SLD 75.1358191541
SLD 75.1408191591
SLD 75.1458191641
SLD 75.1508191691
SLD 75.1558191741
SLD 75.1608191791
SLD 75.1658191841
SLD 75.1708191891
SLD 75.1758191941
SLD 75.1808191991
SLD 75.1858192041
SLD 90.40969591
SLD 90.45969641
SLD 90.50969691
SLD 90.55969741
SLD 90.60969791
SLD 90.65969841
SLD 90.70969891
SLD 90.75969941
SLD 90.80969991
SLD 90.859691041
SLD 90.909691091
SLD 90.959691141
SLD 90.1009691191
SLD 90.1059691241
SLD 90.1109691291
SLD 90.1159691341
SLD 90.1209691391
SLD 90.1259691441
SLD 90.1309691491
SLD 90.1359691541
SLD 90.1409691591
SLD 90.1459691641
SLD 90.1509691691
SLD 90.1559691741
SLD 90.1609691791
SLD 90.1659691841
SLD 90.1709691891
SLD 90.1759691941
SLD 90.1809691991
SLD 90.1859692041
Check Lead Times
Use our handy PDF guide below to check lead time information for the specification you need.

Downloads

Complete Documentation Pack

Download a zip file containing all documents for this product.

  • Technical Data Sheet

  • Declaration of Performance

  • Installation Guide

  • Operation & Maintenance Manual

  • Warranty

  • BIM Model

Download Pack

Technical Data Sheet

Detailed technical information in PDF format
Download PDF

Declaration of Performance

The Declaration of Performance is a key part of the Construction Products Regulation. It provides information on the performance of a product.
Download PDF

Installation Guide

Detailed installation instructions for the SLD
Download PDF

Operation & Maintenance Manual

How to use and care for your Shaft Louvre Damper
Download PDF

Warranty

Product warranty in PDF format
Download PDF

BIM Model

Version: Revit 2022
Download BIM

Videos

Product Video

Two Minute Tuesday – What is a Smoke Control Damper?

2 mins
Product Video

Two Minute Tuesday – Smoke Control Damper Classification: Explained

2 mins
Product Video

Two Minute Tuesday – What Smoke Control Damper Should I Use?

2 mins
Product Video

Two Minute Tuesday – Smoke Control Damper Myths: Busted!

2 mins
Product Video

Two Minute Tuesday – Smoke Control Dampers: Certified, Classified, Tested

2 mins

FAQ

Choose a category
Is the Aerodynamic Free Area available for the SLD?

The aerodynamic area does not apply to dampers or EN12101-8; it is specific to natural smoke vents under EN12101-2.

Do you offer a 1.5m² free area natural vent?

Yes, we can provide our 120.170 SLD, which consists of two 60.170 SLD units.

Where can the actuator be located?

The actuator can be positioned either at the top or the bottom of the SLD.

What is the electrical rating for the SLD?

The standard electrical rating is 24V/0.3A DC, but it can be configured for 230V AC if needed.

Can the SLD be installed in any orientation?

The SLD is certified for vertical installation only and is not approved for horizontal installation.

What is the minimum wall thickness for installation?

The minimum wall thickness required is 125mm for flexible walls.

Can the SLD recess inside the shaft?

Dampers may protrude slightly into the shaft in most cases, but this typically does not pose an issue.

Related Case Studies

Explore real projects using our smoke ventilation products across both residential and commercial sectors.

Merseyside Fire & Rescue Training Academy

Mechanical and natural smoke ventilation products to support realistic fire training scenarios at a Training Academy in the UK.

Sector

Public

System Type

Mechanical, Natural

Client

Maclec

Products

Pod™ Mini, RSL-R, SLD

View Case Study

Station Quarter

Fully mechanical smoke ventilation products for compliant, efficient operation across a new-build residential development in Northamptonshire.

Sector

Low-Rise Residential

System Type

Mechanical

Client

Gallico Systems

Products

Pod™ Mini, RSL-R, SLD

View Case Study

LIV Sheffield

Custom smoke ventilation products delivered seamlessly for a high-rise student accommodation, ensuring both safety and comfort for future residents.

Sector

Student Accommodation

System Type

Mechanical

Client

Advanced Integrated Security Systems

Products

Pod™ Original, RSL-R, SLD

View Case Study

Explore more products in our range
Single Leaf Vent | Glass
View
Single Leaf Vent | Poly
View
Louvred Vent | Solid
View
Louvred Vent | Glass
View
Sertus Pod™ Mini
View
Sertus Pod™ Original
View
Get a Quote
Our friendly and knowledgeable team are ready to help