System type
Customisations available
Lead times
Dedicated Sertus delivery
Fixings and mastic supplied
Hinged grille access
Insulated to I-Rating
Certified and tested for install into various wall types
Pre-drilled casing
Impact and thermal tested
Compact, installation-ready smoke control damper for natural and mechanical systems
Tested for 10,000+ cycles for proven long-term reliability
Hinged white linear grille for easy commissioning and servicing
Integrated control module with dry-fit intumescent seal for quick install
Pre-drilled casing supplied with fixings and mastic – no extra components needed
Suitable for both shaft and duct applications across multi-zone systems
Rear duct or wall-mounted configurations
Compatible with flexible, concrete, and asymmetric wall types
Standard and custom sizes available (up to 969 × 2041 mm)
Steel casing with multi-blade, fire-rated louvres
Certified to BS EN 12101-8:2011 - Fire resistance class EIS 120
Tested to EN 13501-4:2016, EN 1366-2, and EN 1366-10
I-Rated and S1000 rated (up to 750 × 1400 mm)
Impact tested to TN75 and TN76 (with reference to BS 8200)
Bi-directional testing (i↔o) for full compliance in either orientation
Automatic Activation (AA) system for fast smoke response
Multi-compartment compliant - suitable for multi-zone ventilation systems
969 x 2041 mm
30s / 60s
Tested to 10,000 cycles
E120
I120
BS EN 12101-8:2011 / EN 13501-4:2016 / EN 1366-2 / EN 1366-10
S500Pa – 1000Pa (size dependent)
AA (Automatic Activation)
Suitable for multi-zone smoke ventilation
VEW – suitable for vertical wall installation
i↔o – tested both inside-to-outside and outside-to-inside
TN75 & TN76 (ref. BS 8200)
Steel casing with multi-blade fire-rated louvres
Supplied with white linear grille
Includes fixings and mastic
Rear duct or wall-mounted configurations
Dry-fit intumescent seal
Natural and mechanical smoke ventilation
EIS 120
| Model | Overall Width (mm) | Overall Height (mm) |
|---|---|---|
| SLD 30.40 | 369 | 591 |
| SLD 30.45 | 369 | 641 |
| SLD 30.50 | 369 | 691 |
| SLD 30.55 | 369 | 741 |
| SLD 30.60 | 369 | 791 |
| SLD 30.65 | 369 | 841 |
| SLD 30.70 | 369 | 891 |
| SLD 30.75 | 369 | 941 |
| SLD 30.80 | 369 | 991 |
| SLD 30.85 | 369 | 1041 |
| SLD 30.90 | 369 | 1091 |
| SLD 30.95 | 369 | 1141 |
| SLD 30.100 | 369 | 1191 |
| SLD 30.105 | 369 | 1241 |
| SLD 30.110 | 369 | 1291 |
| SLD 30.115 | 369 | 1341 |
| SLD 30.120 | 369 | 1391 |
| SLD 30.125 | 369 | 1441 |
| SLD 30.130 | 369 | 1491 |
| SLD 30.135 | 369 | 1541 |
| SLD 30.140 | 369 | 1591 |
| SLD 30.145 | 369 | 1641 |
| SLD 30.150 | 369 | 1691 |
| SLD 30.155 | 369 | 1741 |
| SLD 30.160 | 369 | 1791 |
| SLD 30.165 | 369 | 1841 |
| SLD 30.170 | 369 | 1891 |
| SLD 30.175 | 369 | 1941 |
| SLD 30.180 | 369 | 1991 |
| SLD 30.185 | 369 | 2041 |
| SLD 45.40 | 519 | 591 |
| SLD 45.45 | 519 | 641 |
| SLD 45.50 | 519 | 691 |
| SLD 45.55 | 519 | 741 |
| SLD 45.60 | 519 | 791 |
| SLD 45.65 | 519 | 841 |
| SLD 45.70 | 519 | 891 |
| SLD 45.75 | 519 | 941 |
| SLD 45.80 | 519 | 991 |
| SLD 45.85 | 519 | 1041 |
| SLD 45.90 | 519 | 1091 |
| SLD 45.95 | 519 | 1141 |
| SLD 45.100 | 519 | 1191 |
| SLD 45.105 | 519 | 1241 |
| SLD 45.110 | 519 | 1291 |
| SLD 45.115 | 519 | 1341 |
| SLD 45.120 | 519 | 1391 |
| SLD 45.125 | 519 | 1441 |
| SLD 45.130 | 519 | 1491 |
| SLD 45.135 | 519 | 1541 |
| SLD 45.140 | 519 | 1591 |
| SLD 45.145 | 519 | 1641 |
| SLD 45.150 | 519 | 1691 |
| SLD 45.155 | 519 | 1741 |
| SLD 45.160 | 519 | 1791 |
| SLD 45.165 | 519 | 1841 |
| SLD 45.170 | 519 | 1891 |
| SLD 45.175 | 519 | 1941 |
| SLD 45.180 | 519 | 1991 |
| SLD 45.185 | 519 | 2041 |
| SLD 60.40 | 669 | 591 |
| SLD 60.45 | 669 | 641 |
| SLD 60.50 | 669 | 691 |
| SLD 60.55 | 669 | 741 |
| SLD 60.60 | 669 | 791 |
| SLD 60.65 | 669 | 841 |
| SLD 60.70 | 669 | 891 |
| SLD 60.75 | 669 | 941 |
| SLD 60.80 | 669 | 991 |
| SLD 60.85 | 669 | 1041 |
| SLD 60.90 | 669 | 1091 |
| SLD 60.95 | 669 | 1141 |
| SLD 60.100 | 669 | 1191 |
| SLD 60.105 | 669 | 1241 |
| SLD 60.110 | 669 | 1291 |
| SLD 60.115 | 669 | 1341 |
| SLD 60.120 | 669 | 1391 |
| SLD 60.125 | 669 | 1441 |
| SLD 60.130 | 669 | 1491 |
| SLD 60.135 | 669 | 1541 |
| SLD 60.140 | 669 | 1591 |
| SLD 60.145 | 669 | 1641 |
| SLD 60.150 | 669 | 1691 |
| SLD 60.155 | 669 | 1741 |
| SLD 60.160 | 669 | 1791 |
| SLD 60.165 | 669 | 1841 |
| SLD 60.170 | 669 | 1891 |
| SLD 60.175 | 669 | 1941 |
| SLD 60.180 | 669 | 1991 |
| SLD 60.185 | 669 | 2041 |
| SLD 75.40 | 819 | 591 |
| SLD 75.45 | 819 | 641 |
| SLD 75.50 | 819 | 691 |
| SLD 75.55 | 819 | 741 |
| SLD 75.60 | 819 | 791 |
| SLD 75.65 | 819 | 841 |
| SLD 75.70 | 819 | 891 |
| SLD 75.75 | 819 | 941 |
| SLD 75.80 | 819 | 991 |
| SLD 75.85 | 819 | 1041 |
| SLD 75.90 | 819 | 1091 |
| SLD 75.95 | 819 | 1141 |
| SLD 75.100 | 819 | 1191 |
| SLD 75.105 | 819 | 1241 |
| SLD 75.110 | 819 | 1291 |
| SLD 75.115 | 819 | 1341 |
| SLD 75.120 | 819 | 1391 |
| SLD 75.125 | 819 | 1441 |
| SLD 75.130 | 819 | 1491 |
| SLD 75.135 | 819 | 1541 |
| SLD 75.140 | 819 | 1591 |
| SLD 75.145 | 819 | 1641 |
| SLD 75.150 | 819 | 1691 |
| SLD 75.155 | 819 | 1741 |
| SLD 75.160 | 819 | 1791 |
| SLD 75.165 | 819 | 1841 |
| SLD 75.170 | 819 | 1891 |
| SLD 75.175 | 819 | 1941 |
| SLD 75.180 | 819 | 1991 |
| SLD 75.185 | 819 | 2041 |
| SLD 90.40 | 969 | 591 |
| SLD 90.45 | 969 | 641 |
| SLD 90.50 | 969 | 691 |
| SLD 90.55 | 969 | 741 |
| SLD 90.60 | 969 | 791 |
| SLD 90.65 | 969 | 841 |
| SLD 90.70 | 969 | 891 |
| SLD 90.75 | 969 | 941 |
| SLD 90.80 | 969 | 991 |
| SLD 90.85 | 969 | 1041 |
| SLD 90.90 | 969 | 1091 |
| SLD 90.95 | 969 | 1141 |
| SLD 90.100 | 969 | 1191 |
| SLD 90.105 | 969 | 1241 |
| SLD 90.110 | 969 | 1291 |
| SLD 90.115 | 969 | 1341 |
| SLD 90.120 | 969 | 1391 |
| SLD 90.125 | 969 | 1441 |
| SLD 90.130 | 969 | 1491 |
| SLD 90.135 | 969 | 1541 |
| SLD 90.140 | 969 | 1591 |
| SLD 90.145 | 969 | 1641 |
| SLD 90.150 | 969 | 1691 |
| SLD 90.155 | 969 | 1741 |
| SLD 90.160 | 969 | 1791 |
| SLD 90.165 | 969 | 1841 |
| SLD 90.170 | 969 | 1891 |
| SLD 90.175 | 969 | 1941 |
| SLD 90.180 | 969 | 1991 |
| SLD 90.185 | 969 | 2041 |
Download a zip file containing all documents for this product.
Technical Data Sheet
Declaration of Performance
Installation Guide
Operation & Maintenance Manual
Warranty
BIM Model
The aerodynamic area does not apply to dampers or EN12101-8; it is specific to natural smoke vents under EN12101-2.
Yes, we can provide our 120.170 SLD, which consists of two 60.170 SLD units.
The actuator can be positioned either at the top or the bottom of the SLD.
The standard electrical rating is 24V/0.3A DC, but it can be configured for 230V AC if needed.
The SLD is certified for vertical installation only and is not approved for horizontal installation.
The minimum wall thickness required is 125mm for flexible walls.
Dampers may protrude slightly into the shaft in most cases, but this typically does not pose an issue.