Search

The Sertus Pod™ Range

A fully engineered, certified modular platform for mechanical smoke extraction.

Sertus Pod™ Mini

Compact smoke extract Pod™ for restricted roof space.

The next-generation Sertus Pod™ Mini delivers full life-safety smoke extract performance within the smallest footprint of the range. Certified to EN12101-3 as a complete modular platform - with both fans and associated ancillary components tested together – it provides compliant, dependable performance without unnecessary complexity.

Factory-built, pre-wired and pre-commissioned, the Pod™ Mini arrives installer-ready for single crane-lift installation. Its extendable adjustable leg system and integrated weathering cap support earlier positioning within the build programme, while the fixed footprint architecture simplifies rooftop coordination and reduces redesign risk if airflow requirements change. 

Ideal for high-rise residential, mixed-use and commercial developments where space, programme and budget control are critical.

Patent pending – application no. 2515965.8

View Product

CompareSertus Pod™ Models

Find the right smoke extract Pod™ for your project. All models are manufactured and supplied by Sertus and follow the same off-site, pre-commissioned, single-lift delivery philosophy – with clear differences in size, acoustic performance and environmental ventilation capability!

Horizontal Range - Pod™ Mini
Horizontal Range - Pod™ Original
Horizontal Range - Pod™ Max
Compact smoke extract Pod™ for restricted roof space.
Smoke extract Pod™ delivering smoke ventilation with integrated environmental ventilation.
High-performance smoke extract Pod™ delivering advanced acoustics and environmental ventilation.

Use cases

Restricted roof or plant space

High-rise residential, mixed-use & commercial buildings

Day-to-day environmental ventilation

Low-noise / acoustically sensitive locations

Direct smoke shaft mounting (no roof-level ductwork)

Restricted roof or plant space

High-rise residential, mixed-use & commercial buildings

Day-to-day environmental ventilation

Low-noise / acoustically sensitive locations

Direct smoke shaft mounting (no roof-level ductwork)

Restricted roof or plant space

High-rise residential, mixed-use & commercial buildings

Day-to-day environmental ventilation

Low-noise / acoustically sensitive locations

Direct smoke shaft mounting (no roof-level ductwork)

System & configuration

Mechanical smoke extraction

Automatic duty / standby fan alternation

400 V three-phase power supply

Maximum load current: 32 A

Motor type: F300 (IE3)

Integrated backdraft damper

Variable speed drive (VSD)

Advanced inverter control

Integrated electrical isolator

Mechanical smoke extraction

Automatic duty / standby fan alternation

400 V three-phase power supply

Maximum load current: 32 A

Motor type: F300 (IE3)

Integrated backdraft damper

Variable speed drive (VSD)

Advanced inverter control

Integrated electrical isolator

Mechanical smoke extraction

Automatic duty / standby fan alternation

400 V three-phase power supply

Maximum load current: 32 A

Motor type: F300 (IE3)

Integrated backdraft damper

Variable speed drive (VSD)

Advanced inverter control

Integrated electrical isolator

Environmental & acoustic performance

37–42 dB sound reduction

Environmental ventilation (optional Roof Enviro Module)

37–42 dB sound reduction

Integrated primary acoustic attenuator

37–42 dB sound reduction

Integrated primary acoustic attenuator

Integrated secondary acoustic attenuator

Size & performance range

Unit dimensions (W x H x L, mm): 1400 × 1310 × 1636

Extract airflow range: 2.1–8.0 m³/s

Static pressure range: 400–450 Pa

Fan size / impeller configuration: 710/90L – 710/132M

Roof load pressure range: 4.15–6.40 kN/m²

Unit dimensions (W x H x L, mm): 1400 × 1310 × 2106

Extract airflow range: 2.1–8.0 m³/s

Static pressure range: 400–450 Pa

Fan size / impeller configuration: 710/90L – 710/132M

Roof load pressure range: 4.76–7.01 kN/m²

Unit dimensions (W x H x L, mm): 1400 × 1310 × 3056

Extract airflow range: 2.1–8.0 m³/s

Static pressure range: 400–450 Pa

Fan size / impeller configuration: 710/90L – 710/132M

Roof load pressure range: 5.23–7.48 kN/m²

Construction & finish

External powder-coated finish: RAL 7016 / RAL 7035

Powder-coated steel enclosure

On-site adjustable legs for roof build-up and duct connection height (250–900 mm in 50 mm increments)

Weathering cap for waterproof termination

Quick-release spring-loaded pin

Thermally broken mounting feet: 430mm

Lifting eyes

Outlet protection louvre

Anti-vibration mounts included

Integrated roof kink for rainwater run-off

External powder-coated finish: RAL 7016 / RAL 7035

Powder-coated steel enclosure

On-site adjustable legs for roof build-up and duct connection height (250–900 mm in 50 mm increments)

Weathering cap for waterproof termination

Quick-release spring-loaded pin

Thermally broken mounting feet: 430mm

Lifting eyes

Outlet protection louvre

Anti-vibration mounts included

Integrated roof kink for rainwater run-off

External powder-coated finish: RAL 7016 / RAL 7035

Powder-coated steel enclosure

On-site adjustable legs for roof build-up and duct connection height (250–900 mm in 50 mm increments)

Weathering cap for waterproof termination

Quick-release spring-loaded pin

Thermally broken mounting feet: 430mm

Lifting eyes

Outlet protection louvre

Anti-vibration mounts included

Integrated roof kink for rainwater run-off

Installation & delivery

Typical unit weight range: 266–409 kg

Off-site manufactured, pre-wired and pre-commissioned

Supplied fully assembled

Single crane-lift installation

Forklift pockets

Plug-and-play setup

Ductwork connection

Lead time: Stock: 4–6 weeks / Made-to-order: 6–8 weeks

Flat-rate £150 delivery fee (UK-wide)

Typical unit weight range: 305–448 kg

Off-site manufactured, pre-wired and pre-commissioned

Supplied fully assembled

Single crane-lift installation

Forklift pockets

Plug-and-play setup

Ductwork connection

Lead time: Stock: 4–6 weeks / Made-to-order: 6–8 weeks

Flat-rate £150 delivery fee (UK-wide)

Typical unit weight range: 335–478 kg

Off-site manufactured, pre-wired and pre-commissioned

Supplied fully assembled

Single crane-lift installation

Forklift pockets

Plug-and-play setup

Ductwork connection

Lead time: Stock: 4–6 weeks / Made-to-order: 6–8 weeks

Flat-rate £150 delivery fee (UK-wide)

Compliance, testing & assurance

Certified to BS EN 12101-3

Factory pre-commissioned and airflow tested

Wind load resistance (qp,max): 0.703–1.217 kN/m²

Patent pending – 2515965.8

CE marked

UKCA marked

Warranty: 5-year Pod™ unit / 2-year fan, motor and controls Learn more

Certified to BS EN 12101-3

Factory pre-commissioned and airflow tested

Wind load resistance (qp,max): 0.863–1.186 kN/m²

Patent pending – 2515965.8

CE marked

UKCA marked

Warranty: 5-year Pod™ unit / 2-year fan, motor and controls Learn more

Certified to BS EN 12101-3

Factory pre-commissioned and airflow tested

Wind load resistance (qp,max): 0.918–1.310 kN/m²

Patent pending – 2515965.8

CE marked

UKCA marked

Warranty: 5-year Pod™ unit / 2-year fan, motor and controls Learn more

Maintenance & sustainability

Access via removable service panels (slide on/off)

Reduced on-site labour and crane requirements

Reduced site deliveries and embodied carbon

Supports Modern Methods of Construction (MMC)

Access via removable service panels (slide on/off)

Reduced on-site labour and crane requirements

Reduced site deliveries and embodied carbon

Supports Modern Methods of Construction (MMC)

Access via removable service panels (slide on/off)

Reduced on-site labour and crane requirements

Reduced site deliveries and embodied carbon

Supports Modern Methods of Construction (MMC)

Options & accessories

Automatic Transfer Switch (ATS)

Push–pull set (mechanical inlet and extract, reversible bi-directional airflow)

Air Inlet Damper

Roof Enviro Module (REM) Learn more

Master-slave set

Automatic Transfer Switch (ATS)

Push–pull set (mechanical inlet and extract, reversible bi-directional airflow)

Air Inlet Damper

Master-slave set

Automatic Transfer Switch (ATS)

Push–pull set (mechanical inlet and extract, reversible bi-directional airflow)

Air Inlet Damper

Master-slave set

Get in touch.
Want to learn more about our products? 😊